Boiler
|
|
Technical caracterictics
| |
Adjustable or fixed temperature coontrol or automatic reset safety limiter |
Adjustable or fixed temperature |
UL/CUL approved equivalents (25A) |
| Type |
Single pole single throw |
Single pole double throw with changeover contact |
Single pole single throw |
Single pole double throw with changeover contact |
Single pole double throw with automatic reset |
Single pole double throw with manual reset |
| Temperature range |
35°C to 350°C (-31°F to 662°F, customized to specification ) |
| Differential |
5% of temperature range |
| Rating |
20 A - 250 V |
| Material |
Bulb and capillary in copper, nickel-plated copper, or stainless steel |
| Capillary length |
150 to 3 000 mm |
| Sensing element diameters |
Copper: 45,6,6.5 and 8mm Stainless steel |
| Maximum head temperature |
120°C/ 248°F, 150°C/ 302°F |
| Connections |
Brass or nickel plated fastons or screw terminals |
| Approvals |
CE, EN 60730, BEAB, UL |
Diagram
Weight : 60g